N-architect
Copyright N-architect

N-architect

  • HOME
  • CONTACT
  • PROFILE
  • PROJECTS
Copyright N-architect

N-architect

POSITIVE ENERGY HOUSING

Boulogne, France
Housing
12 000m2
2006

 

The purpose of this project was to achieve a positive energy building, which means a building that produce more energy than it actually needs. The production is not really an issue because it relies on the area you can allow for the energy producing devices such as solar panel and photovoltaic panels. The real challenge of this project was to be able to design a housing building located in Paris, France, that (almost) won’t need any heating energy during the winter, without causing overheating during summer. Assisted by a thermical simulator, the project has been checked, step by step, to insure the realism of the design. The main components of this energy efficient are green houses lobbies (open during summer) to collect the heat during day time, and 40cm thick earth brick walls to store and diffuse the heat during night time. Orientation and solar protection for the windows helped completing the zero energy strategy for the building. On top of that, the free space between the different blocks has been turned into phyto-restoration pounds and gardens to treat and re-use the rain water.

 


 

L’idée de ce projet était de concevoir un bâtiment à énergie positive, soit un édifice qui produit plus d’énergie qu’il n’en dépense. La production d’énergie en soit n’est pas problématique, car elle est liée à la surface possible pour y intégrer des panneaux solaires et panneaux photovoltaïques. La véritable difficulté de ce projet a été de concevoir un bâtiment, situé a proche de Paris, qui pourrait fonctionner pratiquement sans chauffage en hiver et sans surchauffe en été, et ce, de manière naturelle, sans consommation d’énergie. Assisté par un logiciel de simulation thermique tout au long de la conception, la viabilité du projet a ainsi pu être vérifiée tout au long du processus de conception. Les principaux composants de cette efficacité thermique sont, les serres présentes à chaque hall d’entrée, qui permettent de collecter l’énergie solaire la journée, ainsi que des murs en terre cuite de 40cm d’épaisseurs afin de distribuer progressivement cette chaleur durant la nuit, par inertie. Les choix d’orientation et protection solaires ont ensuite aidé à rendre le bâtiment passif énergétiquement. De plus, afin de tirer partie au maximum du site, un jardin de phyto-restauration est proposé, afin de retraiter les eaux pluviales et les utiliser comme eau sanitaire.

Related Posts

ZERO WASTE CENTER

ZERO WASTE CENTER

St Denis, France Industrial 5 000m2 2007   Since the last few years, the relationship between society and waste that it produces has dramatically evolved. From a linear way of thinking (product to waste), we are now moving to a cycling vision (product A to waste A to product B …). If this relationship changes, […]

KB STADIUM

KB STADIUM

Kelantan, Malaysia Facility 10 000m2 2011   The sultan of Kelantan, northern region of Malaysia, aspires to bring up his region on the front line of Malaysia’s development. KB stadium, a 40,000 seats facility, is in the heart of this move forward. Home of the Kelantan Red Warriors, this stadium aims to host soccer games […]

GRACE HOTEL

GRACE HOTEL

Kuala Lumpur, Malaysia Hospitality 12 000m2 2009   Grace Hotel is a 3-stars business hotel project located in centre of Kuala Lumpur. Sitting on top of an 8-storey shopping mall podium, the 30 storey hotel propose green side walls and roofs. The rooftop of the building integrates three restaurants with garden terrace and spectacular view […]

SAN FRANSISCO FIRE DEPT. HQ

SAN FRANSISCO FIRE DEPT. HQ

San Fransisco, USA Facility 5 000m2 2013   This project was designed for an International ideas competition, which goal was to design an HQ for the Fire Department of San Fransisco. The proposal was following three main concept ideas: PUBLIC SPACE Ground level is given back to the pedestrians and bicycles. a musuem of the […]

LEAVE A COMMENT CANCEL REPLY